Know-how for job preparers and engineers
Answers to the questions asked on site and in sales support. With sizes, tables and sources, and honest about what is indicative.
24 articles · 9 topics
Strut channel
41x21 vs 41x41 strut channel: loads, weight and use
Shallow 41x21 or standard 41x41 strut channel? Depth, weight, stiffness and span load tables compared, with the right channel nut and a worked trapeze example.
5 min readH-frame vs cantilever arm: choosing a strut support
H-frame vs cantilever arm for cable tray and pipework: floor-standing frames, wall brackets and christmas tree brackets compared on load, arm length and fixing.
6 min readPre-galvanised vs hot-dip galvanised vs stainless strut
Pre-galvanised vs hot-dip galvanised vs stainless 316 strut channel: zinc thickness, corrosivity classes C1 to CX, expected life and a finish for each location.
5 min readUnistrut channel sizes: P1000, P3300 and back-to-back
Standard Unistrut channel sizes from P1000 to P5001: dimensions, gauge, weight per metre, slot patterns, finishes, lengths and whether solid beats slotted.
Threaded rod
How to assemble a trapeze bracket in seven steps
Assemble a trapeze bracket for cable tray, basket or ladder in seven steps: width, load, cross member, drop rods, ceiling fixing and fitting, with a full BOM.
7 min readThreaded rod load table: M6 to M20 studding capacity
Indicative safe tensile load of M6 to M20 threaded rod (studding) in kN and kg for grades 4.8 and 8.8, with stress areas, the formula and the weakest link.
Cable tray
Cable tray fill calculation: formula, table and margin
Cable tray fill calculation made simple: the formula, cross-sections of common cables, capacity tables for UK basket sizes and the margin to design for.
6 min readCable tray supports: spacing, trapezes and fixings
Cable tray supports explained: the six common support types, how far tray and ladder can span, where couplers go, load per support and which fixings to use.
6 min readFire rated cable tray: circuit integrity E30 to E90
Fire rated cable tray and ladder explained: what E30, E60 and E90 mean, FE180 against E90, UK standards, what changes in the supports and how to check parts.
5 min readPower and data cable segregation in containment
Power and data cable segregation on tray, basket and ladder: what BS 7671 and BS EN 50174-2 require, five site options, divider heights and crossings.
Ladder and basket
Cable basket fixing: brackets, drop rods and spacing
Cable basket fixing to soffit, wall or floor: six fixing methods, support spacing, cutting bends, couplers, earth continuity and common UK sizes and finishes.
5 min readCable ladder vs cable tray vs cable basket: which to use
Cable ladder vs cable tray vs cable basket compared: construction, UK duty ratings and sizes, support spacing and use, plus a five-question selection guide.
Fixings
Beam clamp guide: types, flange thickness and loads
How to choose a beam clamp for threaded rod and strut channel: universal, external, internal and Z clamps, with working loads, flange ranges and fitting tips.
5 min readCeiling anchors for threaded rod: which fixing to use
Ceiling anchors for threaded rod: drop-in, concrete screw, wedge or resin anchor by slab type, with cracked concrete, the ETA, hollowcore and site testing.
5 min readChannel nuts and spring nuts for strut: types and fitting
Channel nuts for strut channel: plain, short spring, long spring, plastic retainer and stud nuts. Sizes M6 to M16, which nut suits which channel, how to fit.
Data cables
Cat6A vs fibre: what goes where in the containment
Cat6A vs fibre for your containment route: reach, PoE, diameter, space in the basket, bend radius and segregation, with a comparison table and worked example.
5 min readCustom length data cables measured from the route
Custom length data cables made to the containment route: measuring each link, which pre-terminated cables to order, labelling, bundling and one order.
5 min readMPO/MTP trunk cables: types, polarity and routing
Choosing and installing MPO trunk cables: MPO-8, -12, -16 and -24, trunks and fan-outs, polarity methods A, B and C, pinning, loss, length and routing.
Data centres and prefab
Data centre cable management: routes, trays and cabling
How to plan data centre cable management from the soffit down: overhead or underfloor routes, containment sizes, fill, segregation and support loads.
5 min readPrefabricated trapeze brackets for data centres
Prefabricated trapeze brackets for data centres: why offsite, build-up and sizes, indicative channel capacities, what the request needs and how install works.
5 min readRaised access floor cabling: basket, depth and airflow
Raised access floor cabling: underfloor or overhead, a lane layout per aisle, fixing basket to the slab, keeping airflow clear, bonding, fire and water.
Comparing brands
Locations
Ceiling void supports: hanging services above a ceiling
Supporting services in the ceiling void: void depth, layering of ductwork and containment, 41x21 or trapeze, access, sprinklers and BS 7671 fire support.
5 min readRoof support blocks for strut: flat roof spacing and wind
Roof support blocks carry strut on flat roofs without penetrating the membrane. Build-up, spacing, wind uplift, membrane protection, lightning and finish.
See your own range in 3D.
In 30 minutes we show how your installers configure, what arrives on your side and what the client version on your range involves.
Book a demo with Ismail
You see the configurator in your own brand and we discuss your range, systems and markets.
Reply from Ismail within one working day
Configure for free
A trapeze, frame or tray with cables in a few minutes, with a bill of materials and drawing.
Enquiry goes to a supplier · reply within one working day