# Strutconfigurator > The 3D configurator for strut, support and cable management systems. Installers configure trapeze brackets, H-frames, cantilevers and containment with the cables inside and receive a bill of materials, cutting list and drawing. Manufacturers and wholesalers get the configurator on their own range and in their own brand. Part of NEXTRIQ (Rotterdam). - Languages: Dutch and English (strutconfigurator.nl and strutconfigurator.com). - The public configurator is free and brand-independent. - Loads are indicative and based on manufacturer data; the manufacturer confirms. - Data stored in the EU (Frankfurt, Neon eu-central-1); runs on the Cloudflare network. - No prices on the site; the investment is discussed in a conversation. - Configurator: https://strutconfigurator-app.pages.dev - Deep links: every configuration opens via URL parameters, for example https://strutconfigurator-app.pages.dev/?lang=en&systeem=trapeze&tiers=2&breedte=600&goot=ladder-500x100&kabels=5g16x8 (system, tiers, width in mm, containment per tier, cables as type×quantity). - Open standard catalogue (JSON, brand-independent, indicative): /api/catalogus.json, with an OpenAPI description at /api/catalogus.openapi.json. - Every core and knowledge base page is also available as markdown: the same path ending in .md instead of the trailing slash. ## Who it is for - [Your system, configured by installers themselves](https://strutconfigurator-site.pages.dev/en/for-manufacturers/): Strutconfigurator builds manufacturers a 3D configurator on their own range, in their own brand. Installers put together trapezes, frames, cantilevers and containment with your products and rules. You receive complete enquiries with a bill of materials and cutting list, and see what the market configures by sector, region and size. - [Sell systems, not loose items](https://strutconfigurator-site.pages.dev/en/for-wholesalers/): For technical wholesalers, Strutconfigurator builds a 3D configurator on their own range, even when that range comes from several manufacturers. Installers configure complete supports with containment and cables, 24/7. The enquiry arrives with a bill of materials and cutting list, in your brand and with your part numbers. - [Your supports in a few minutes, with a bill of materials](https://strutconfigurator-site.pages.dev/en/for-installers/): With Strutconfigurator, installers and job preparers configure a trapeze bracket, H-frame, cantilever or containment with cables in 3D, free of charge. You get a bill of materials, cutting list and drawing as PDF. When you want to order, your enquiry goes to a supplier, who contacts you within one working day. ## Systems and applications - [Strut channel cut to length](https://strutconfigurator-site.pages.dev/en/strut-channel/): Strut channel is a 41 mm wide steel C-section with a 22 mm slot opening in which channel nuts lock. Common depths are 21, 41, 62 and 82 mm, supplied in 3 or 6 m lengths. Cutting to length before delivery saves installation time and offcuts on site. - [Trapeze bracket builder: from rod to containment](https://strutconfigurator-site.pages.dev/en/trapeze-bracket-builder/): A trapeze bracket consists of two threaded rods from the soffit with one to four strut channel beams between them, the tiers. Each tier carries a cable tray, ladder or basket. You set the width, the spacing between tiers, the rod size and the drop; the configurator turns it into a bill of materials. - [H-frame: the floor-standing frame for pipes and containment](https://strutconfigurator-site.pages.dev/en/h-frame/): An H-frame is a free-standing frame of two strut channel uprights with one or more beams between them, anchored with base plates. It is used on floors, in plant rooms and on roofs, for pipes, cable trays and small units. Height, width and the number of beams drive the bill of materials. - [Cantilever arms: containment along the wall](https://strutconfigurator-site.pages.dev/en/cantilever-arm/): A cantilever arm is a projecting strut channel arm with a base plate, fixed to a wall, column or wall channel. Common arm lengths run from 150 to 750 mm in 41×21 and up to 1,000 mm in 41×41, in 150 mm steps. A christmas tree bracket has arms on both sides of a single upright. - [Cable tray supports: tray and supports in one go](https://strutconfigurator-site.pages.dev/en/cable-tray-supports/): Cable tray is supported on trapeze brackets from threaded rod, on cantilever arms along a wall or on a centre hanger. Support spacing is usually between 1.2 and 1.5 m (rule of thumb); the tray manufacturer gives the permitted span for your tray and load. Also place a support close to every bend and coupler. - [Cable ladder: for heavy cables and long spans](https://strutconfigurator-site.pages.dev/en/cable-ladder/): A cable ladder consists of two side rails with rungs between them, usually 60, 100 or 150 mm deep and 100 to 1,000 mm wide, in 3 or 6 m lengths. Rungs sit at 250 to 300 mm centres. Choose a ladder for heavy power cables, long spans and industrial environments. - [Cable basket supports: light, open and easy to change](https://strutconfigurator-site.pages.dev/en/cable-basket-supports/): Cable basket is supported on a centre hanger from a single threaded rod, on a trapeze, with a C-bracket or wall support, or on an omega support profile. Common sizes are 35, 60 or 100 mm deep (UK also 30, 55 and 106) and 100 to 600 mm wide, in 3 m lengths. Join sections with quick couplers and bond them to earth. - [Roof supports: strut on flat roofs](https://strutconfigurator-site.pages.dev/en/roof-supports/): A roof support block is a rubber or plastic base, usually 200 × 200 mm, with a strut channel on top. It carries cable routes, pipes, HVAC units and panels on a flat roof by gravity, without penetrating the roof membrane. You set the height and channel length; the load spreads over the roof. - [Data cables to length, in the same bill of materials as the route](https://strutconfigurator-site.pages.dev/en/data-cables-to-length/): With data cables to length alongside the route, you choose which cables go into the containment in the same configuration: Cat6A, fibre (OM4, OS2, MPO trunks) and power. The configurator calculates the fill ratio, checks power and data segregation and adds the cables to length, with connectors and labels, to the bill of materials. - [Data centre cable management, from the soffit down](https://strutconfigurator-site.pages.dev/en/data-centres/): Data centre cable management starts above the racks: trapeze brackets with two to four tiers, carrying cable basket for data and fibre and cable ladder for power. Keep power and data segregated, check the fill ratio per tier and the load per threaded rod, and have the manufacturer confirm every load. - [Prefab supports: from configuration to pallet](https://strutconfigurator-site.pages.dev/en/prefab-supports/): Prefabricated trapeze brackets are supports cut and assembled in a workshop and delivered to site per position. That requires a drawing, bill of materials and cutting list for every position. Strutconfigurator generates them from the configuration, so workshop and site work from the same data. - [Commercial buildings: everything above the ceiling](https://strutconfigurator-site.pages.dev/en/sectors/commercial-buildings/): In commercial buildings cable routes run above suspended ceilings, in perforated cable trays and cable baskets on trapeze brackets or centre hangers. Indoors in dry areas, pre-galvanised material is standard. Strut also carries chilled ceilings, ductwork and lighting. Hang everything from the structure above, never from the ceiling grid. - [Industry and petrochemical: heavy, galvanised and vibration-proof](https://strutconfigurator-site.pages.dev/en/sectors/industry-and-petrochemical/): In industry and petrochemical sites, use heavy 100 or 150 mm cable ladders on cantilevers and trapezes of 41×41 or back-to-back channel. Hot-dip galvanised steel (HDG) is the baseline; in aggressive environments choose stainless 316. Watch vibration, expansion over long runs and access for maintenance. - [Food and pharma: open, smooth and easy to clean](https://strutconfigurator-site.pages.dev/en/sectors/food-and-pharma/): In food and pharma, use stainless 316 cable baskets and open channel that trap little dirt and are easy to clean. Avoid closed trays and horizontal surfaces where water stands. Keep clearance from walls and ceilings so you can clean around them. The configurator advises stainless 316 for hygienic environments. - [Infrastructure, tunnels and rail: cantilevers along the wall](https://strutconfigurator-site.pages.dev/en/sectors/infrastructure-tunnels-and-rail/): In infrastructure, tunnels and rail, cables are carried on cantilever arms along the wall, with cable ladders or trays in hot-dip galvanised or stainless steel. Choose corrosion-resistant materials against moisture and de-icing salt, keep routes accessible for maintenance and check circuit integrity requirements with the manufacturer. - [Solar and roofs: routes and frames on flat roofs](https://strutconfigurator-site.pages.dev/en/sectors/solar-and-roofs/): On a flat roof, lay cable routes, pipes and units on strut channel on roof support blocks, without penetrating the membrane. Use hot-dip galvanised steel outdoors, spread the load over enough blocks and allow for wind load. A covered cable tray protects cables from UV and debris. - [Marine and offshore: against salt, vibration and movement](https://strutconfigurator-site.pages.dev/en/sectors/marine-and-offshore/): In marine and offshore settings, use marine cable ladder in stainless 316, or hot-dip galvanised steel where permitted. They are built to resist salt water and vibration. Use joints that do not shake loose, separate dissimilar metals to prevent galvanic corrosion and follow the requirements of classification societies and the client. ## Tools - [Threaded rod load M6 to M20](https://strutconfigurator-site.pages.dev/en/tools/threaded-rod-load-calculator/) - [Strut load per span](https://strutconfigurator-site.pages.dev/en/tools/strut-load-calculator/) - [Cable tray fill](https://strutconfigurator-site.pages.dev/en/tools/cable-fill-calculator/) - [ROI calculator for manufacturers and wholesalers](https://strutconfigurator-site.pages.dev/en/roi-calculator/) ## About and trust - [How it works](https://strutconfigurator-site.pages.dev/en/how-it-works/) - [Capabilities, honestly labelled](https://strutconfigurator-site.pages.dev/en/capabilities/) - [Integrations](https://strutconfigurator-site.pages.dev/en/integrations/) - [Trust: hosting, GDPR and data](https://strutconfigurator-site.pages.dev/en/trust/) - [About us](https://strutconfigurator-site.pages.dev/en/about/) - [Book a demo](https://strutconfigurator-site.pages.dev/en/demo/) - [Demo in your own brand](https://strutconfigurator-site.pages.dev/en/branded-demo/) ## Knowledge base - [How to assemble a trapeze bracket in seven steps](https://strutconfigurator-site.pages.dev/en/knowledge-base/assemble-trapeze-bracket/): Assemble a trapeze bracket for cable tray, basket or ladder in seven steps: width, load, cross member, drop rods, ceiling fixing and fitting, with a full BOM. - [Beam clamp guide: types, flange thickness and loads](https://strutconfigurator-site.pages.dev/en/knowledge-base/beam-clamp-guide/): How to choose a beam clamp for threaded rod and strut channel: universal, external, internal and Z clamps, with working loads, flange ranges and fitting tips. - [Cable basket fixing: brackets, drop rods and spacing](https://strutconfigurator-site.pages.dev/en/knowledge-base/cable-basket-fixing/): Cable basket fixing to soffit, wall or floor: six fixing methods, support spacing, cutting bends, couplers, earth continuity and common UK sizes and finishes. - [Cable ladder vs cable tray vs cable basket: which to use](https://strutconfigurator-site.pages.dev/en/knowledge-base/cable-ladder-vs-cable-tray-vs-basket/): Cable ladder vs cable tray vs cable basket compared: construction, UK duty ratings and sizes, support spacing and use, plus a five-question selection guide. - [Cable tray fill calculation: formula, table and margin](https://strutconfigurator-site.pages.dev/en/knowledge-base/cable-tray-fill-calculation/): Cable tray fill calculation made simple: the formula, cross-sections of common cables, capacity tables for UK basket sizes and the margin to design for. - [Cable tray supports: spacing, trapezes and fixings](https://strutconfigurator-site.pages.dev/en/knowledge-base/cable-tray-supports/): Cable tray supports explained: the six common support types, how far tray and ladder can span, where couplers go, load per support and which fixings to use. - [Cat6A vs fibre: what goes where in the containment](https://strutconfigurator-site.pages.dev/en/knowledge-base/cat6a-vs-fibre-containment/): Cat6A vs fibre for your containment route: reach, PoE, diameter, space in the basket, bend radius and segregation, with a comparison table and worked example. - [Ceiling anchors for threaded rod: which fixing to use](https://strutconfigurator-site.pages.dev/en/knowledge-base/ceiling-anchors-for-threaded-rod/): Ceiling anchors for threaded rod: drop-in, concrete screw, wedge or resin anchor by slab type, with cracked concrete, the ETA, hollowcore and site testing. - [Channel nuts and spring nuts for strut: types and fitting](https://strutconfigurator-site.pages.dev/en/knowledge-base/channel-nuts-spring-nuts/): Channel nuts for strut channel: plain, short spring, long spring, plastic retainer and stud nuts. Sizes M6 to M16, which nut suits which channel, how to fit. - [Fire rated cable tray: circuit integrity E30 to E90](https://strutconfigurator-site.pages.dev/en/knowledge-base/circuit-integrity-e30-e90/): Fire rated cable tray and ladder explained: what E30, E60 and E90 mean, FE180 against E90, UK standards, what changes in the supports and how to check parts. - [Compare strut systems: Unistrut, Hilti, Sikla, Walraven](https://strutconfigurator-site.pages.dev/en/knowledge-base/compare-strut-systems/): A neutral comparison of strut support systems: Unistrut, Hilti, Sikla, Walraven, MÜPRO, fischer, OBO and Gripple, with design software and selection criteria. - [Custom length data cables measured from the route](https://strutconfigurator-site.pages.dev/en/knowledge-base/custom-length-data-cables/): Custom length data cables made to the containment route: measuring each link, which pre-terminated cables to order, labelling, bundling and one order. - [Data centre cable management: routes, trays and cabling](https://strutconfigurator-site.pages.dev/en/knowledge-base/data-centre-cable-management/): How to plan data centre cable management from the soffit down: overhead or underfloor routes, containment sizes, fill, segregation and support loads. - [Roof support blocks for strut: flat roof spacing and wind](https://strutconfigurator-site.pages.dev/en/knowledge-base/flat-roof-strut-supports/): Roof support blocks carry strut on flat roofs without penetrating the membrane. Build-up, spacing, wind uplift, membrane protection, lightning and finish. - [H-frame vs cantilever arm: choosing a strut support](https://strutconfigurator-site.pages.dev/en/knowledge-base/h-frame-vs-cantilever-arm/): H-frame vs cantilever arm for cable tray and pipework: floor-standing frames, wall brackets and christmas tree brackets compared on load, arm length and fixing. - [MPO/MTP trunk cables: types, polarity and routing](https://strutconfigurator-site.pages.dev/en/knowledge-base/mpo-mtp-trunk-cables/): Choosing and installing MPO trunk cables: MPO-8, -12, -16 and -24, trunks and fan-outs, polarity methods A, B and C, pinning, loss, length and routing. - [Power and data cable segregation in containment](https://strutconfigurator-site.pages.dev/en/knowledge-base/power-data-cable-segregation/): Power and data cable segregation on tray, basket and ladder: what BS 7671 and BS EN 50174-2 require, five site options, divider heights and crossings. - [Pre-galvanised vs hot-dip galvanised vs stainless strut](https://strutconfigurator-site.pages.dev/en/knowledge-base/pre-galvanised-vs-hot-dip-galvanised-vs-stainless/): Pre-galvanised vs hot-dip galvanised vs stainless 316 strut channel: zinc thickness, corrosivity classes C1 to CX, expected life and a finish for each location. - [Prefabricated trapeze brackets for data centres](https://strutconfigurator-site.pages.dev/en/knowledge-base/prefabricated-trapeze-brackets/): Prefabricated trapeze brackets for data centres: why offsite, build-up and sizes, indicative channel capacities, what the request needs and how install works. - [Raised access floor cabling: basket, depth and airflow](https://strutconfigurator-site.pages.dev/en/knowledge-base/raised-access-floor-cabling/): Raised access floor cabling: underfloor or overhead, a lane layout per aisle, fixing basket to the slab, keeping airflow clear, bonding, fire and water. - [41x21 vs 41x41 strut channel: loads, weight and use](https://strutconfigurator-site.pages.dev/en/knowledge-base/strut-channel-41x21-vs-41x41/): Shallow 41x21 or standard 41x41 strut channel? Depth, weight, stiffness and span load tables compared, with the right channel nut and a worked trapeze example. - [Ceiling void supports: hanging services above a ceiling](https://strutconfigurator-site.pages.dev/en/knowledge-base/supports-above-suspended-ceiling/): Supporting services in the ceiling void: void depth, layering of ductwork and containment, 41x21 or trapeze, access, sprinklers and BS 7671 fire support. - [Threaded rod load table: M6 to M20 studding capacity](https://strutconfigurator-site.pages.dev/en/knowledge-base/threaded-rod-load-table/): Indicative safe tensile load of M6 to M20 threaded rod (studding) in kN and kg for grades 4.8 and 8.8, with stress areas, the formula and the weakest link. - [Unistrut channel sizes: P1000, P3300 and back-to-back](https://strutconfigurator-site.pages.dev/en/knowledge-base/unistrut-channel-sizes/): Standard Unistrut channel sizes from P1000 to P5001: dimensions, gauge, weight per metre, slot patterns, finishes, lengths and whether solid beats slotted.